TGR Series Thermochillers
Water-Cooled Thermochillers
The TGR Series is a water-cooled combination chiller with an optional heater. Available in multiple configurations including single and dual temperature zone. With integrated free-cooling and customizable P4 or P6 pumps, it is a great option for a variety of processes. The 3-way mixing valve allows the unit to intercept and mix heat transfer fluids from the heating and cooling system to either mix or divert the flow and best control temperatures. Each unit uses environmentally friendly R513A refrigerant and are engineered with integrated free-cooling to achieve the maximum energy savings.


TGR Series Benefits
- Looking for an energy efficient, environmentally friendly thermochiller? The TGR Series is what you need. Other benefits include:
- High, constant and increasing productivity
- Optimization of the overall process performance
- Reduction of cycle times and perfect repeatability
- Improvement of the cooling precision
- Quality of the molded components
- Energy saving
- Friendly maintenance
- Small footprint
Available Models
- TGR008
- TGR012
- TGR017
- TGR021
- TGR021
- TGR030
- TGR035
- TGR048
- TGR060
ELECTRICAL PANEL
→ Manufactured in compliance with international standards (EN 60204-1) using UL components
→ Disconnect switch with door lock prevents access to panel when energized
→ Watertight door prevents access to the electronic controls
→ Circuit breakers for compressor, fans, pumps, and tank heater
→ Contacts for remote ON/OFF operation and remote alarm indication
→ Phase sequence relay
ELECTRONIC CONTROLLER
→ Multiple controller parameters access levels
(User / Service / Manufacturer)
→ Automatic management of cooling, heating and free cooling functions
→ Integrated display with clear icons for a real time monitoring of the TGR operations and any alarm status, recording up to the last 20 faults occurred
→ RS485 MODBUS RTU protocol communication
→ Remote Start / Stop – Remote General alarm
REFRIGERANT CIRCUIT
The activity of the TGR thermo-chiller is based on a vapor compression cycle implemented in the chiller circuit and made up of these components:
-
- Evaporator
- Compressor
- Condenser
- Electronic Expansion Valve
- Electronic Hot Gas Bypass Valve
The TGR Series can also work in free cooling mode when the return water temperature from the central cooling system (condensation side) is cold enough to satisfy the user water setpoint and it consequently allows to switch off the refrigerating compressor for energy savings.


FACTORY TESTING OF EVERY UNIT
- Every model tested with full load!
- Additional tests include:
- Correct components assembly
- Pressing of refrigerating circuit and for leak by means of a leak-finder
- Pressing of hydraulic circuit
- Electrical safety tests in compliance with European standards
- Check of correct functioning of protections and safety devices
- Check of correct functioning of the electronic controller
- Thermal performance and electric quantities measurement
- Final sniffer leak detection
BREWERY SERIES
Made with Breweries in Mind
Chase Cooling Systems’ brewery specific units have cooling capacities up to 4 tons based on glycol temperatures typically required for brewing processes. Larger capacities may be available upon request. The plug-and-play design comes preassembled with all necessary adjustments already made and is ready for installation & startup upon delivery. The package includes a standardized pump and compressor.
Standard construction on these glycol chillers includes a powder-coated galvanized steel cabinet, microprocessor temperature controller, and all necessary instrumentation and safety devices. An optional stainless-steel cabinet provides enhanced corrosion protection and cohesion with other common brewery equipment.


Brewery Specific Modifications
- Fluid circuit configured with warm tank to minimize back pressure on brewing equipment
- Insulated fluid hoses to minimize sweating
- Controller programming adjustments for proper customizable temperature control
- Low pressure safety switch selection for system protection
- Thermal expansion valve (TXV) adjustment to maintain proper superheat
- Can accommodate glycol concentrations up to 50%
Modifications make these units appropriate for low glycol temperatures and satisfy most brewery requirements. Further customization may be available. Contact a Chase Cooling Systems representative with your requirements for more information.
REFRIGERATION CIRCUIT
- Manufactured with high-quality materials following rigorous brazing procedures and conforming to international standards (PED 97/23/EC)
- Environmentally friendly R407C refrigerant
- Refrigerant sight glass with moisture indicator (BR-QBE009-025) and filter-dryer
- Externally equalized thermostatic expansion valve
- High and low pressure switches
- High and low pressure gauges (BR-QBE009-025)
- High and low pressure access fittings for maintenance and troubleshooting
- Optional Hot Gas Bypass Valve for highly accurate control of outlet fluid temperature
COMPRESSOR
- Hermetic compressors (scroll, rotary, or reciprocating) chosen for reliability and efficiency
- Mounted on rubber isolators for noise reduction
- Scroll compressors are especially quiet and can handle liquid return without damage
- Three-phase models are protected against reverse rotation by an electronic phase monitor
- Crankcase heater prevents liquid slugging on start-up
EVAPORATOR
- Copper coaxial evaporators are especially reliable when dealing with contaminated fluids
- Stainless steel, brazed plate evaporators (BR-QBE009-025) are compact and highly efficient
- Evaporators are protected against freezing by the microprocessor controller
CONDENSER
- Microchannel design is compact and highly efficient
- All-aluminum construction eliminates the risk of galvanic corrosion
- Epoxy-coated for corrosion resistance, even in aggressive environments
- Cleanable, stainless steel air filter (standard on BR-QBE009-025, optional on BR-QBE003-007)
- Condenser fan motor includes internal, self-resetting thermal protector
ELECTRICAL PANEL
- Manufactured in compliance with international standards (EN 60204) using UL-recognized components
- Electrical cabinet constructed of powder-coated galvanized steel
- Disconnect switch with door lock prevents access to panel when energized (BR-QBE009-025)
MICROPROCESSOR CONTROLLER
- Optimizes unit performance and maintains fluid temperature
- Controls and displays the fluid temperature
- Turns the compressor on and off while protecting against short cycling
- Turns the pump and condenser fan on and off
- Protected by a watertight cover
- Displays key operating parameters and the following alarm conditions
- High and low refrigerant pressure
- Low fluid differential pressure (BR-QBE009-025)
- Low fluid level
- Incorrect phase sequence (BR-QBE009-025)
- Compressor, pump, or fan motor protector tripped (BR-QBE009-025)
- Temperature probe failure
- High fluid temperature
- Evaporator anti-freeze
UNIT CONSTRUCTION & MAINTENANCE
-
- Standard cabinet frame and panels are powder-coated
- Optional Stainless Steel Cabinet
- Panels are easily removed, providing convenient access for maintenance and repair
- All fasteners are stainless or zinc-plated steel for corrosion resistance
- Protection to IP44 standard on three-phase models
- For ease of installation all models include lifting eyes; BR-QBE009-025 also have lifting holes in the base
- Wheel kits are available for all models
- Designed for ease of operation and maintenance
- Some models suitable for outdoor installation
FACTORY TESTING OF EVERY UNIT
- Pressurization and helium leak detection of refrigeration circuit
- Pressurization and leak testing of fluid circuit
- Chiller performance and power consumption at full load
- Proper operation of all controls, safety devices, and alarms
- Electrical tests according to international standards (EN 60204)

FLUID CIRCUIT
- Standard insulated plastic tank (unpressurized)
- Optional pressurized tank
- Tank includes fill port, drain valve, level gauge, and level sensor
- Insulated, non-ferrous centrifugal pump and fluid circuit minimizes corrosion
- Fluid bypass protects pump from damage if chiller inlet and outlet are closed
- Fluid differential pressure switch (BR-QBE009-025) protects against low-flow condition
- Fluid pressure gauge (pump discharge)
- Ability to use glycol mixtures up to 50%
RENTALS
For Short- Or Long-Term Needs
Chase Cooling Systems provides rental equipment to satisfy short or long term requirements for commercial or industrial cooling. We provide expert engineering, maintenance, and support staff. We want to make your equipment transition as smooth as possible. Whether your need for a chiller rental is weeks away or right now, contact us today to get the process started.
Chase Cooling Systems maintains an inventory of rental chillers with cooling capacities ranging from ½ to 40 tons. Work with our in-house engineering staff to select the optimally sized unit. We seek to meet your cooling requirements, whether planned or an emergency.
Rental chillers are most commonly needed in the following scenarios:
- Planned shutdown or equipment failure –
Keep your process or production line going even when your existing chiller is out of service. Rental units from Chase Cooling Systems can cover both planned or unplanned events.
- Supplemental cooling required –
A rental chiller can provide additional cooling during temporary periods of reduced performance from your existing equipment. Also possible to use for additional needs due to increased production demands.
- Capital limitations –
To reduce your company’s upfront costs, a rental contract can be configured as “rent-to-own.” Contact us for additional details.
For more information on renting a chiller from Chase Cooling Systems, contact us today.

CWB
CWB Series chillers deliver high cooling capacity (up to 150 tons) to meet the requirements of centralized or plant-wide applications. All units operate on 460/3/60 power and include variable speed condenser fans, tandem scroll compressors, and stainless steel brazed plate evaporators. The chiller package is designed for outdoor installation and allows for easy access for maintenance and repair. The microprocessor controller features a communications port and a user interface with a multi-line display for clear indication of operating parameters and alarms. Single or duplex pumps with various pressure ratings, pressurized or unpressurized tanks, non-ferrous fluid circuit, and remote control panel are among the many options offered on CWB Series chillers.


FLUID CIRCUIT
- Standard models include a stainless steel, brazed plate evaporator, without tank or pump
- Options include single and dual pumps in a variety of pressures
- Available with insulated tank in carbon steel or stainless steel
- Optional non-ferrous fluid circuit
- Fluid differential pressure switch protects evaporator against low-
flow condition - Fluid pressure gauge (pump discharge pressure)
- Ability to use glycol mixtures up to 50%
REFRIGERATION CIRCUIT
- Manufactured with high-quality materials following rigorous brazing procedures and conforming to international standards (PED 2014/68/EU)
- Environmentally friendly R410A refrigerant
- Refrigerant sight glass with moisture indicator and filter-dryer
- Electronic expansion valve and liquid line solenoid valve
- High and low pressure transducers and switches
- High and low pressure gauges
- High and low pressure access fittings for maintenance and troubleshooting
COMPRESSOR
- Tandem, hermetic scroll compressors chosen for reliability
and efficiency - Multiple compressors for energy efficiency and low starting amps
- Mounted on rubber isolators for noise reduction
- Scroll compressors are especially quiet and can handle liquid return without damage
- Protected against reverse rotation by an electronic phase monitor
- Crankcase heater prevents liquid slugging on start-up
EVAPORATOR
- Stainless steel, brazed plate evaporators are compact and highly efficient
- Evaporators are protected against freezing by the microprocessor controller
- Evaporator has two refrigerant circuits and a single fluid circuit
(CWB270 to CWB570)
CONDENSER
- Microchannel design is compact and highly efficient
- All-aluminum construction eliminates the risk of galvanic corrosion
- Variable-speed fans allow operation over a wide ambient
temperature range
ELECTRICAL PANEL
- Manufactured in compliance with international standards (EN 60204) using UL-recognized components
- Electrical cabinet constructed of powder-coated galvanized steel
- Disconnect switch with door lock prevents access to panel when energized
MICROPROCESSOR CONTROLLER
- Optimizes unit performance and maintains fluid temperature
- Controls and displays the fluid temperature
- Turns the compressors on and off while protecting against short cycling
- Turns the pump(s) on and off; equalizes pump operating times
(double pump models) - Regulates condenser fan speed
- Protected by a watertight cover
- Displays key operating parameters and the following alarm conditions
- High and low refrigerant pressure
- High refrigerant discharge temperature
- Low fluid differential pressure
- Incorrect phase sequence
- Compressor, pump, or fan motor protector tripped
- Temperature probe or pressure sensor failure
- High fluid temperature
- Evaporator anti-freeze
- Electronic expansion valve fault
- Optional remote control panel
UNIT CONSTRUCTION AND MAINTENANCE
- Cabinet frame and panels are powder-coated and suitable for outdoor installation
- Panels are easily removed, providing convenient access for maintenance and repair
- All fasteners are stainless or zinc-plated steel for corrosion resistance
- Protection to IP54 standard on all models; suitable for outdoor installation
- Designed for ease of operation and maintenance
FACTORY TESTING OF EVERY CWB UNIT
- Pressurization and helium leak detection of refrigeration circuit
- Pressurization and leak testing of fluid circuit
- Chiller performance and power consumption at full load
- Proper operation of all controls, safety devices, and alarms
- Electrical tests according to international standards (EN 60204)
HEAT EXCHANGERS
Compatibility
Heat exchangers can be used when the fluid to be cooled is not compatible with the chiller or dry cooler in terms of temperature, pressure, flow rate, or material compatibility. We supply plate heat exchangers (gasketed, brazed or welded) and shell and tube heat exchangers to meet your specific application requirements. The heat exchanger can be a stand-alone unit or it can be part of a pump skid as needed.

GLYCOL MAKE-UP SYSTEMS
Pressure Control
A glycol make-up system automatically maintains proper fluid pressure in a closed cooling system. The make-up system consists of a pump, non-pressurized storage tank, and all necessary controls. If the cooling system pressure falls below the user-adjustable set point, glycol is pumped from the storage tank to restore the pressure to an acceptable level.

HEAT TRANSFER FLUIDS
Handling Low Fluid Temperatures
Glycol-water mixtures should be used to protect chillers and dry coolers against freezing in applications requiring low fluid temperatures and/or in outdoor installations. Pre-mixed solutions are available in various concentrations, based on the lowest expected temperature. The type of glycol (ethylene or propylene) and concentration must be considered upfront to ensure proper performance in terms of heat transfer and fluid flow. Inhibited glycols contain additives to provide corrosion protection in fluid systems that are not non-ferrous.

DRY COOLERS
Alternate Cooling
Dry coolers use ambient air to cool process fluids, with cooling capacities to 250 tons. Multiple units can be employed to handle even greater heat loads. Configuration choices include horizontal or vertical air discharge, single or double row fans, and vertical, horizontal or V mounted coils. Units can have multiple circuits, multiple passes and can be configured to be piped in series or parallel. The rugged, weather-proof design is manufactured with corrosion-resistant galvanized steel sheet, finished with high quality polyurethane paint. Standard cooling coils consist of copper tubes and aluminum fins, which are coupled with high efficiency, low noise fans. A variety of optional fan controls can be provided, including step controls and variable speed drives in single- and three-phase voltages to match your electric power supply.

FILTERS & STRAINERS
Protecting Your Equipment
Protect your chiller and other critical cooling equipment from solid particle contamination using filters and strainers.
Thompson brand strainers feature flow ratings from 100 to 2000 GPM at a pressure drop of 1 PSI. These units include large conical strainers providing substantially more surface area than traditional strainers. Non-ferrous construction consists of a 304SS housing with 316SS screens as fine as 250 mesh (50 micron). Options include automatic timer flush valve, differential pressure alarm package, and alternate materials of construction.
Helix Series filters are an economical choice for removal of particles as small as 50 micron. Single filters are rated for 100 or 200 GPM; manifold multiple units together for higher flow rates. These units are non-ferrous with housings made of polyamide, fitted with either a depth-filtration cartridge (polypropylene) or a perforated or mesh screen (316SS).

COOLING TOWERS
Keeping Things Cool
Chase Cooling Systems proudly offers the full selection of cooling towers available from Delta Cooling Towers. For over 45 years, Delta’s primary focus has been to manufacture a virtually maintenance free line of corrosion-proof, engineered HDPE cooling towers. All products incorporate a unitary molded structure, with a high efficiency counter-flow design. Unlike metal towers, the engineered plastic cooling towers will not rust, flake, chip or need re-coating downtime. Factory assembled models range from 10-2600 tons, are simple to install, and can be molded in any color. We also offer an Anti-Microbial Cooling Tower with anti-microbial HDPE resin, which is fully compounded throughout that resists biofilm and microorganism growth. Products are made in the USA and have a standard 20-yr shell warranty, the longest in the industry.